Can novel technologies improve breast conserving surgery?

The Original Article was published on 09 July 2018

The practice of breast conserving surgery has been transformative for management of women’s breast cancer [1], and yet the current practice remains in a situation where approximately one-third of all patients have incomplete surgical resection. This is measured by the finding of clear margins on the surgical specimen, as measured by pathology sampling. This is a very active area of professional debate and research study [2], and the solutions are not as obvious as one might guess. Still, reviews of the status of the field suggest that technical solutions should be available to help mitigate this issue [3], and the tools for molecular phenotyping of tissues need to be deployed if they can provide rapid, specific diagnoses.

The paper by Shipp et al. [4] published in this issue presents one of the most promising technologies to molecular fingerprint a tissue, through Raman spectroscopy. In particular, the hypothesis in this paper is that, through a combination of fluorescence imaging to map a tissue macroscopically (4 × 6.5 cm2) and Raman spectroscopy to fingerprint several microscopic areas, the strengths of each might be combined into a better overall tool for a fast, surgical environment. Raman spectroscopy has incredible potential for specificity because of the nature of generating dozens to hundreds of molecular-specific vibrational bands from each sample. Yet, its limitations of long acquisition time, low signal to noise, and some non-specific peaks have hampered the translation of this from individual investigator studies into multicenter studies. However, even though optimized and ‘fast’ acquisitions systems have been presented for over two decades [5, 6], discoveries in the past few years of how to further maximize the signal and thereby improve the speed of acquisition have been important [7, 8]. Additionally, being able to capture Raman signals in a noisy light environment has been an issue, which can be partially solved by collection geometry and partially solved by smart algorithms [9]. Similarly, improved data processing methods with accurate and robust discriminant analysis are important, as presented in the work of Shipp et al.

One of the strengths of their study is the dual phased approach to validating the system, where the spectral training was done on frozen tissues with known pathology (n = 91 frozen samples) and this trained algorithm was then utilized on a separate set of tissues (n = 70 frozen samples). Once validated this way, in the second phase they next applied the approach to image and classify freshly resected specimens (n = 51), achieving 100% sensitivity and 80% specificity.

While this study is promising, there are still limitations which need to be addressed in future research work; these are in the areas of 1) sufficient pathobiology sampling, 2) hardware optimization, and 3) software optimization. All of these will need to be solved prior to any real commercial translation [10]. The study used a good variation of tumor and normal/benign tissue subtypes, but the large number of these illustrates the need for higher sample numbers, because with three types of carcinoma and tumors, DCIS, three benign tumors, inflammation, and four types of normal tissues the range expected in sampling is high, and even with 51 samples this range cannot be covered adequately with sufficient statistics. Systems with this potential specificity will need hundreds to thousands of tissues to gain robust stable classification of undiagnosed tissues. In the area of hardware, the acquisition time of 12–14 min is too long to be useful for most surgery applications, and so improvements in automation of acquisition and optimization are required. The current approach of imaging through a window is likely essential for automation, and so this places some major constraints on the geometry and applications possible. Finally, as systems emerge which might go into multicenter trials or regulatory clearance, factors that affect the algorithms and need for calibration and retraining will require careful thought. These post-processing and classification algorithms can be non-linear and saturable in nature, and so careful attention to making them as robust as possible will be essential, and this can only be verified with the largest possible data sets. It is possible that future banks of known classified tissue spectra could be used to test and calibrate systems with the appropriate controls on their use.

Still, despite these limitations, this single site study presents two major steps forward in the ability to do molecular fingerprinting of surgical tissues, by first showing that a combination of optical imaging tools can speed up the choice of tissues to sample, and secondly that analysis by Raman spectroscopy appears stable from training on frozen tissues to freshly resected tissues in the breast.

References

  1. Morrow M, Van Zee KJ, Solin LJ, Houssami N, Chavez-MacGregor M, Harris JR, Horton J, Hwang S, Johnson PL, Marinovich ML, Schnitt SJ, Wapnir I, Moran MS. Society of Surgical Oncology-American Society for Radiation Oncology-American Society of Clinical Oncology consensus guideline on margins for breast-conserving surgery with whole-breast irradiation in ductal carcinoma in situ. J Clin Oncol. 2016;34(33):4040–6.

    Article  PubMed  PubMed Central  Google Scholar 

  2. Brouwer de Koning SG, Vrancken Peeters M, Jozwiak K, Bhairosing PA, Ruers TJM. Tumor resection margin definitions in breast-conserving surgery: systematic review and meta-analysis of the current literature. Clin Breast Cancer. 2018.

  3. Gray RJ, Pockaj BA, Garvey E, Blair S. Intraoperative margin Management in Breast-Conserving Surgery: a systematic review of the literature. Ann Surg Oncol. 2018;25(1):18–27.

    Article  PubMed  Google Scholar 

  4. Shipp DW, Rakha EA, Koloydenko AA, Macmillan RD, Ellis IO, Notingher I. Intra-operative spectroscopic assessment of surgical margins during breast conserving surgery. Breast Cancer Res. 2018;20(1):69.

    Article  PubMed  PubMed Central  Google Scholar 

  5. Manoharan R, Shafer K, Perelman L, Wu J, Chen K, Deinum G, Fitzmaurice M, Myles J, Crowe J, Dasari RR, Feld MS. Raman spectroscopy and fluorescence photon migration for breast cancer diagnosis and imaging. Photochem Photobiol. 1998;67(1):15–22.

    Article  PubMed  CAS  Google Scholar 

  6. Motz JT, Gandhi SJ, Scepanovic OR, Haka AS, Kramer JR, Dasari RR, Feld MS. Real-time Raman system for in vivo disease diagnosis. J Biomed Opt. 2005;10(3):031113.

    Article  PubMed  CAS  Google Scholar 

  7. Jermyn M, Desroches J, Aubertin K, St-Arnaud K, Madore WJ, De Montigny E, Guiot MC, Trudel D, Wilson BC, Petrecca K, Leblond F. A review of Raman spectroscopy advances with an emphasis on clinical translation challenges in oncology. Phys Med Biol. 2016;61(23):R370–400.

    Article  PubMed  CAS  Google Scholar 

  8. Wilson BC. Detection and treatment of dysplasia in Barrett's esophagus: a pivotal challenge in translating biophotonics from bench to bedside. J Biomed Opt. 2007;12(5):051401.

    Article  PubMed  Google Scholar 

  9. Jermyn M, Desroches J, Mercier J, Tremblay MA, St-Arnaud K, Guiot MC, Petrecca K, Leblond F. Neural networks improve brain cancer detection with Raman spectroscopy in the presence of operating room light artifacts. J Biomed Opt. 2016;21(9):94002.

    Article  PubMed  Google Scholar 

  10. Wilson BC, Jermyn M, Leblond F. Challenges and opportunities in clinical translation of biomedical optical spectroscopy and imaging. J Biomed Opt. 2018;23(3):1–13.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Contributions

The author read and approved the final manuscript.

Corresponding author

Correspondence to Brian W. Pogue.

Ethics declarations

Competing interests

The author declares that he has no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Pogue, B.W. Can novel technologies improve breast conserving surgery?. Breast Cancer Res 20, 85 (2018). https://0-doi-org.brum.beds.ac.uk/10.1186/s13058-018-1016-9

Download citation

  • Published:

  • DOI: https://0-doi-org.brum.beds.ac.uk/10.1186/s13058-018-1016-9